Search results for "Mass-to-charge ratio"
showing 6 items of 6 documents
Diagnostics for studies of novel laser ion acceleration mechanisms.
2014
Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel accelera…
The REX-ISOLDE project
2002
REX-ISOLDE is a pilot experiment at ISOLDE/CERN to study the structure of neutron-rich nuclei (N=20, N=28) with post-accelerated radioactive ion beams (1). Therefore radioactive ions with charge state 1+, which are delivered by the online mass separator ISOLDE, are accelerated up to 2.2 MeV/u by means of a new concept. The radioactive ions are first accumulated in a Penning trap, then charge breeded to a charge-to-mass ratio of 1/4.5 in an Electron Beam Ion Source (EBIS) and finally accelerated. The LINAC consists of three components, namely a Radio Frequency Quadrupole (RFQ) accelerator, which accelerates the ions from 5 to 300 keV/u, an interdigital H-type structure (IH) with a final ener…
Status of REX-ISOLDE
2003
REX-ISOLDE [1] is a post-accelerator situated at the ISOLDE radioactive ion beam facility placed at CERN, Geneva. It’s main aim is to increase the energy of light (A < 50) radioactive ions from 60 keV to 0.8–2.2MeV/u. REX—ISOLDE uses a new concept of post-acceleration of radioactive ion beams by using charge breeding of the ions in a high charge state ion source and the efficient acceleration of the highly charged ions in a short LINAC using modern ion accelerator structures. In a first step the radioactive ions are captured in a large gas-filled Penning trap. The task is to accumulate, cool and bunch the beam and prepare it for the injection into an electron beam ion source (EBIS). Cooling…
High-precision measurement of the atomic mass of the electron
2014
A very precise measurement of the magnetic moment of a single electron bound to a carbon nucleus, combined with a state-of-the-art calculation in the framework of bound-state quantum electrodynamics, gives a new value of the atomic mass of the electron that is more precise than the currently accepted one by a factor of 13. The atomic mass of the electron is a key parameter for fundamental physics. A precise determination is a challenge because the mass is so low. Sven Sturm and colleagues report on a new determination of the electron's mass in atomic units. The authors measured the magnetic moment of a single electron bound to a reference ion (a bare nucleus of carbon-12). The results were …
First heavy ion beam tests with a superconducting multigap CH cavity
2018
Physical review accelerators and beams 21(2), 020102 (2018). doi:10.1103/PhysRevAccelBeams.21.020102
Prolonging in utero-like oxygenation after birth diminishes oxidative stress in the lung and brain of mice pups☆
2013
Background Fetal-to-neonatal transition is associated with oxidative stress. In preterm infants, immaturity of the antioxidant system favours supplemental oxygen-derived morbidity and mortality. Objectives To assess if prolonging in utero-like oxygenation during the fetal-to-neonatal transition limits oxidative stress in the lung and brain, improving postnatal adaptation of mice pups. Material and methods Inspiratory oxygen fraction (FiO2) in pregnant mice was reduced from 21% (room air) to 14% (hypoxia) 8–12 h prior to delivery and reset to 21% 6–8 h after birth. The control group was kept at 21% during the procedure. Reduced (GSH) and oxidized (GSSG) glutathione and its precursors [γ-glut…